Solar Calculator Canada

Solar Power Calculator for Edmundston, New Brunswick, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Edmundston
  • GPS Coordinates: 47.377222, -68.294444
  • Elevation: 241 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technoloty: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Edmundston: 40o
  • Average yearly irradiance: 1462.15 kWh/m2
  • Average yearly power output: 124163 kWh
Sun Path Edmundston

Average yearly irradiance delivered by the Sun in Edmundston is 1462.15/kWh/m2 at the optimal panel slope of 40o. After taking all losses into account, you can expect about 124163 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 40o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.78 86.08
February 3.57 100.05
March 4.33 134.29
April 4.75 142.52
May 5.07 157.18
June 5.11 153.38
July 5.4 167.33
August 5.21 161.37
September 4.46 133.82
October 3.15 97.71
November 2.29 68.7
December 1.93 59.72
Total yearly 1462.15

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 264.24 8191.44
February 333.45 9336.65
March 390.35 12101
April 408.18 12245.5
May 418.84 12984
June 410.77 12323
July 428.4 13280.3
August 415.83 12890.6
September 365.14 10954.1
October 267.62 8296.1
November 202.01 6060.21
December 177.43 5500.33
Total yearly 124163

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) fals between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Edmundston solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 180.94 5609.29
February 257.52 7210.43
March 342.8 10626.9
April 400.8 12023.9
May 441.6 13689.5
June 447.53 13426
July 459.2 14235.3
August 419.56 13006.4
September 334.3 10029
October 220.84 6846.19
November 146.34 4390.1
December 119.41 3701.76
Total yearly 114795

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 201.14 6235.33
February 276.79 7750
March 356.77 11059.8
April 406.81 12204.4
May 441.18 13676.6
June 443.88 13316.3
July 457.19 14172.9
August 423.45 13126.9
September 344.68 10340.5
October 233.38 7234.91
November 160.11 4803.23
December 133.36 4134.26
Total yearly 118055

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 219.48 6803.94
February 293.95 8230.55
March 368.49 11423.3
April 410.63 12318.8
May 438.96 13607.7
June 438.34 13150.2
July 453.38 14054.9
August 425.02 13175.7
September 352.99 10589.8
October 244.34 7574.54
November 172.55 5176.64
December 146.06 4527.81
Total yearly 120634

Edmundston Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 235.93 7313.97
February 308.97 8651.13
March 377.96 11716.6
April 412.13 12364
May 435.05 13486.7
June 431.49 12944.7
July 447.45 13871
August 424.4 13156.3
September 359.2 10776.1
October 253.68 7864.1
November 183.64 5509.24
December 157.47 4881.57
Total yearly 122535

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.85% angle of incidence loss and -2.88% temperature and irradiance loss. This totals to about -15.08%%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels loose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.